Folding Glass Wall Test Douments and Data:


Air Infiltration Test - ASTM E283 Conducted on 10/21/04
  • Force of 1.57 psf (25 mph) = 0.03 cfm/ft2 infiltration
  • Force of 6.24 psf (50 mph) = 0.06 cfm/ft2 infiltration
Water Infiltration Test - ASTM E331 and E547 Conducted on 10/21/04
  • Water pressure of 9.75 psf and 5.0 gph/ft2 = no leakage
Folding Glass Wall Testing
Uniform Structural Load Test - ASTM E330 Conducted on 10/21/04
  • Force of 120.0 psf exterior = 0.008" permanent set (overload)
  • Force of 120.0 psf interior = 0.004" permanent set (overload)
  • Approximately 215 mph wind load
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a four panel folding wall unit, 126.75" in width and 84.5" in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Thermal Penetration Test -
AAMA 1503-9 Conducted on 12/31/04
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.47 BTU/hr/ft2/°F
  • Condensation Resistance Factor of Frame (CRFf) = 54
  • Condensation Resistance Factor of Glass (CRFg) = 71
  • Condensation Resistance Factor of Specimen (CRF) = 54

  • (Tested with 1/8" Cardinal LoE2-140® over 1/8" clear tempered glass, 1" insulated unit. Better values are attainable using higher performance glass combinations.)
Hurricane Impact Test Conducted on 10/6/06
  • Dade County Test Standards and Protocol (+/- 60.0 PSF)
    • Series 5000ST Aluminum Outfold Doors #07-0326.07
    • Series 5000ST Aluminum Infold Doors #07-1012.06
  • Florida Product Approved - FL#8355.1
  • Click here for a video of the folding glass wall hurricane testing.

National Fenestration Rating Council Product Approval 12/14/07

  • Two Fold, Folding Glass Wall Unit measuring 79" wide by 79" high
  • Click here for Folding Glass Wall testing documents online.
  • Tested U-Value 0.43
  • Standard U-Value 0.46

Back to Top


 Sliding Glass Doors Series 8000 Test Documents and Data:

 


Air Infiltration Test - ASTM E283 Conducted on 7/16/07
  • Force of 6.24 psf (50 mph) = 1.5L and 0.03 cfm/ft2 infiltration
  • Force of 6.24 psf (50 mph) = 1.5L and 0.03 cfm/ft2 infiltration
Water Infiltration Test - ASTM E331 and E547 Conducted on 7/16/07
  • Water pressure of 96 psf and 5.0 gph/ft2 = no leakage
Folding Glass Wall Testing
Uniform Structural Load Test - ASTM E330 Conducted on 7/16/07
  • Force of 60.0 psf exterior = 0.28" permanent set (overload)
  • Force of 60.0 psf interior = 0.28" permanent set (overload)
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing an XO sliding glass door unit, 123.125" in width and 95.125" in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Thermal Penetration Test -
AAMA 1503-98 Conducted on 7/16/07
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.40 BTU/hr/ft2/°F
  • Condensation Resistance Factor (CRF) = 49
Certified test results listed above in the areas of Thermal Penetration reflect testing an OX sliding glass door unit, 97" in width and 97" in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Hurricane Impact Test Conducted on 7/16/07
  • Florida Product Approved - FL#10067
  • ASTM E1886/1996 (Wind Zone 4; HVHZ)
    • +/- 60.0 psf Interior and Exterior

National Fenestration Rating Council Product Approval 12/14/07

  • OX Sliding Glass Door Unit measuring 79" wide by 79" high
  • Click here for Sliding Glass Door testing documents online.
  • Tested U-Value 0.40
  • Standard U-Value 0.40
Certified test results listed above in the areas of Hurricane Impact Testing reflect testing an OOXX sliding glass door unit, 190.5" in width and 96.75" in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Back to Top


Terrace Door Test Documents and Data:


Air Infiltration Test -
ASTM E283 Conducted on 12/30/04
  • Force of 1.57 psf (25 mph) = 0.02 cfm/ft2 infiltration
  • Force of 6.24 psf (50 mph) = 0.04 cfm/ft2 infiltration
Water Infiltration Test - ASTM E331 and E547 Conducted on 12/30/04
  • Water pressure of 6.75 psf and 5.0 gph/ft2 = no leakage
Uniform Structural Load Test - ASTM E330 Conducted on 12/30/04
  • Force of 67.5 psf exterior = 0.005" permanent set (overload)
  • Force of 67.5 psf interior = 0.007" permanent set (overload)
  • Approximately 162 mph wind load
Testing of Terrace Door
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a single swing Terrace Door, 40" in width and 96" in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Thermal Penetration Test - AAMA 1503-98 Conducted on 1/5/05
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.55 BTU/hr/ft2/°F
  • Condensation Resistance Factor (CRF) = 49
  • (Tested with 1/8" Cardinal LoE2-140® over 1/8" clear tempered glass, 1" insulated unit. Better values are attainable using higher performance glass combinations.)
Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.
  • Florida Product Approved - FL#6712

Back to Top


 Casement Windows Test Documents and Data:

 

Air Infiltration Test - ASTM E283 Conducted on 2/17/05
  • Force of 6.24 psf (50 mph) = 0.02 cfm/ft2 infiltration
Water Infiltration Test - ASTM E331 and E547 Conducted on 2/17/05
  • Water pressure of 12 psf and 5.0 gph/ft2 = no leakage
Uniform Structural Load Test - ASTM E330 Conducted on 2/17/05
  • Force of 120.0 psf exterior = 0.010"
  • Force of 120.0 psf interior = 0.003"
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a single Casement Window, 24 " in width and 48 1/16 " in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Thermal Penetration Test - AAMA 1503-98 Conducted on 3/21/05
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.31 BTU/hr/ft2/°F
  • Condensation Resistance Factor (CRF) = 57
Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.

Back to Top


 Awning/Vent Windows Test Documents and Data:

 

Air Infiltration Test - ASTM E283 Conducted on 2/17/05
  • Force of 6.24 psf (50 mph) = 0.02 cfm/ft2 infiltration
Water Infiltration Test - ASTM E331 and E547 Conducted on 2/17/05
  • Water pressure of 12 psf and 5.0 gph/ft2 = no leakage
Uniform Structural Load Test - ASTM E330 Conducted on 2/17/05
  • Force of 120.0 psf exterior = 0.010"
  • Force of 120.0 psf interior = 0.003"
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a single Casement Window, 24 " in width and 48 1/16 " in height. Certified test results listed above in the areas of Thermal Performance on a single Awning Window, 44 5/16 " in width and 44 5/16 " in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Thermal Penetration Test - AAMA 1503-98 Conducted on 3/17/05
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.55 BTU/hr/ft2/°F
  • Condensation Resistance Factor (CRF) = 40
Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.

Back to Top


Curb Mount Skylight Test Documents and Data:

Air Infiltration Test - AAMA/NAFS Section 5.3.2 Conducted on 4/1/05
  • Force of 1.57 psf (25 mph) = 0.05 cfm/ft² infiltration
Water Infiltration Test - AAMA/NAFS Section 5.3.3 Conducted on 4/1/05
  • Water pressure of 6.0 psf and 5.0 gph/ft² = no leakage
Uniform Structural Load Test - AAMA/WDMA 1600/IS 7-2000 Conducted on 4/1/05
  • Force of 120.0 psf positive = 0.005" permanent set (overload)
  • Force of 120.0 psf negative = 0.010" permanent set (overload)
Uniform Structural Load Test - ICC ES AC17 Conducted on 4/1/05
  • Force of 160.0 psf positive = 0.000" permanent set (overload)
  • Force of 160.0 psf negative = 0.004" permanent set (overload)
Testing of Terrace Door
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a single pre-glazed, pre-assembled curb mount pyramid skylight, 7.0' square. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.
  • Florida Product Approval FL#6711.1

Back to Top


Standard Skylight Test Documents and Data:

Air Infiltration Test - ICC ES AC17 Conducted on 10/24/05
  • Force of 1.57 psf (25 mph) = 0.08 cfm/ft² infiltration
Water Infiltration Test - ICC ES AC17 Conducted on 10/24/05
  • Water pressure of 2.86 psf and 5.0 gph/ft² = no leakage
Uniform Structural Load Test - ICC ES AC17 Conducted on 10/24/05
  • Force of 80.0 psf exterior = 0.005" permanent set (overload)
  • Force of 80.0 psf interior = 0.004" permanent set (overload)
  • Approximately 215 mph wind load
Testing of Terrace Door
Certified test results listed above in the areas of Air, Water, and Structural Loads reflect testing on a rectangular based, double pitch skylight, 88 1/4" long, 84 1/2" wide and 45 1/8" overall height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.
Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.

Back to Top


 Fixed Skylights/Curtain Wall Panels Test Documents and Data:

Certified test results listed above in the areas of Thermal Penetration reflect testing on a rectangular fixed skylight or curtain wall panel measuring 48 " in width and 72 " in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Thermal Penetration Test - AAMA 1503-98 Conducted on 1/13/07
  • Thermal transmittance (U Factor) @ 15mph exterior dynamic wind velocity = 0.35 BTU/hr/ft2/°F
  • Condensation Resistance Factor (CRF) = 68

Hurricane Impact Test -
  • Ongoing testing to certify various models as needed to meet large missile impact requirements for Miami-Dade County Building Code.

Back to Top


 Curtain Wall/Sunroom Panels (Aluminum) Test Documents and Data:

Air Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Air Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Water Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Water Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Uniform Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Uniform Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07
Certified test results listed above all of the above areas reflect testing on a unit measuring 51 " in width and 99 " in height. These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Impact and Cycling Test (Monolithic Glazing)
  • ASTM E1886/1996

Impact and Cycling Test (Insulated Glazing)

  • ASTM E1886/1996

Back to Top


 Curtain Wall/Sunroom Panels (Wood) Test Documents and Data:

Air Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Air Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Water Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Water Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07
These certified test results for the above listed size are representations of “average” performance levels for that product and in no way represent the test results for all possible sizes and configurations of said product. Hurricane certification process is underway and additional testing will continue to be conducted. Please contact Solar Innovations™ for current test results.

Uniform Structural Load Test (Monolithic Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Uniform Structural Load Test (Insulated Glazing)

  • AAMA 501-05 Conducted on 12/20/07
  • ASTM E283, E331, E330 Conducted on 12/20/07

Back to Top


We will be happy to assist you or answer any questions. Please call 800-618-0669 or e-mail us at info@solarinnovations.com.